Quality & Certifications
Quality is a documented process, not a claim
Our integrated management system covers quality, environment and occupational health and safety, supported by in-house testing and full batch traceability.
Philosophy
Specify, control, verify, record
A cable or conductor is judged years after it leaves the plant. We therefore treat documentation as part of the product: process parameters, test values and material records are retained so that any despatch can be reconstructed and explained.
Integrated Management System
Three systems, one framework
- ISO 9001:2015
- Quality management
- ISO 14001:2015
- Environmental management
- ISO 45001:2018
- Occupational health and safety
Process
One continuous quality process
Raw material, manufacturing, testing, inspection, traceability and dispatch operate as a single connected sequence.

Step 01
Raw material
Aluminium, copper, compounds and armouring material verified against specification on receipt.
Step 02
Manufacturing
Process parameters monitored at drawing, stranding, extrusion and armouring stages.
Step 03
Testing
Electrical, mechanical and dimensional tests carried out on every length as required.
Step 04
Inspection
Sample-based acceptance tests performed with customer or third-party witness where required.
Step 05
Traceability
Batch records link raw material, process data and test results to the despatched drum.
Step 06
Dispatch
Length verification, sealing, marking and documentation completed before despatch.

Certification library
Certificates and standards, as evidence not a wall of logos
Certificates are published with number, issuing authority and validity. Expired certificates are withdrawn from public view.
- ISO 9001:2015
- Quality Management System — Design, manufacture and supply
- ISO 14001:2015
- Environmental Management System — Manufacturing operations
- ISO 45001:2018
- Occupational Health & Safety — Manufacturing operations
- UL 44
- Thermoset insulated wires and cables — XHHW-2, RHH/RHW-2 and Type L2 constructions
- UL 1685
- Vertical-tray fire propagation and smoke release — Cable tray rated constructions
- UL 854
- Underground service entrance cable — Aluminium USE-2 construction
- CSA C22.2 No. 38 (RW90)
- Thermoset insulated wires and cables — Canadian market constructions
- ASTM B3, B8, B230, B231, B800, B801
- Aluminium and copper conductor material — Conductor standards
- ASTM B-856 (ACSS), B-549 (ACSR/AW)
- Bare overhead conductors — Product standards
- ICEA S-76-474
- Service drop cable — Duplex and quadruplex assemblies
- ANSI/ICEA S-95-658 / NEMA WC-70
- Insulation construction — Product standard
- Telcordia GR-347-CORE
- Central office power cable — Type L2 LSZH construction
Client verification required: Certificate numbers, issuing authority, issue and expiry dates, and current RDSO/BIS approval status. No certificate preview is published before verification.