Skip to content
OSWAL CABLESCables · Conductors · EPC

MVCC

Medium Voltage Covered Conductor (MVCC) is designed for medium-voltage applications, typically from 11 kV to 33 kV. Its cross-linked polyethylene covering helps protect the conductor from sunlight, moisture and other environmental sources of damage while supporting safe and efficient overhead power distribution.

  • MVCC
  • MVCC

Key features

Engineered characteristics

  • Enhanced safety through a protective insulation layer
  • Protection against mechanical damage, corrosion, rain, UV radiation and temperature fluctuations
  • Compact design for high-density installations
  • Reduced risk of direct contact faults and short circuits
  • Protective construction intended to reduce maintenance requirements

Applications

Where it is used

  • Overhead power distribution lines
  • Urban and suburban areas
  • High environmental stress areas
  • Areas with vegetation
  • Coastal and harsh environments
  • High-altitude installations
  • Industrial facilities
  • Renewable energy projects, including solar and wind farms
  • Railway electrification

Construction

What it's built from

Conductor
Longitudinally watertight stranded all aluminium alloy (AAAC), AL-7, AL-59, AL-59 Aluminium Clad Steel (ACS), or ACSR.
Shielding
Semi-conducting cross-linked polymer.
Inner covering
Low-density track-resistant cross-linked polyethylene without carbon black.
Outer covering
High-density UV- and track-resistant cross-linked polyethylene.

Technical specifications

Sizes & ratings

MVCC — nominal layer thickness

Cable attributeUOM11 kV22 kV33 kV
Aluminium Alloy WireSq.mmAs requiredAs requiredAs required
Longitudinal Water Blocking LayermmAs requiredAs requiredAs required
Semi-Conductive Layermm0.30.30.4
Inner XLPE Insulation Without Carbon Blackmm1.21.322.43
UV & Track-Resistant XLPE Outer Insulationmm1.11.11.2

MVCC — AAAC / AL-7 / AL-59 constructions

DescriptionConstructionType
507 strandsAAAC / AL-7 / AL-59
557 strandsAAAC / AL-7 / AL-59
707 strandsAAAC / AL-7 / AL-59
807 strandsAAAC / AL-7 / AL-59
907 strandsAAAC / AL-7 / AL-59
1007 strandsAAAC / AL-7 / AL-59
12019 strandsAAAC / AL-7 / AL-59
12519 strandsAAAC / AL-7 / AL-59
14819 strandsAAAC / AL-7 / AL-59
15919 strandsAAAC / AL-7 / AL-59
16019 strandsAAAC / AL-7 / AL-59
23219 strandsAAAC / AL-7 / AL-59
24119 strandsAAAC / AL-7 / AL-59

MVCC — AL-59 ACS constructions

DescriptionACS strandsAL-59 strandsType
31.616AL-59 ACS
52.8816AL-59 ACS
78.8216AL-59 ACS
104.9816AL-59 ACS
120726AL-59 ACS
160730AL-59 ACS
241730AL-59 ACS

Standards

Referenced specifications

  • IEC 61089
  • IS 398-2
  • BS EN 50182 / 50397

Downloads